Registration

Login

PRODUCTS

WBU

Features
  • High accuracy. For versatile applications.
  • Filled with inactive gases.
  • Combined with metallic bellows that are excellent in environmental characteristics.
  • Covering a low capacity range (10N to 2kN).
  • Supplied with an inspection data sheet to both tension and compression directions.
  • Accuracy Class: 0.015%.

Appearance Dimensions

Model and Capacity / Dimension / etc. (unit : mm)

ModelCapacityABCDEFGHJKLMNNatural frequencyWeight
WBU-10N10 N118432432202720721222448.5M80.16 kHz250 g
WBU-20N20 N118432432202720721222448.5M80.2 kHz250 g
WBU-50N50 N118432432202720721222448.5M80.3 kHz250 g
WBU-100N100 N118432432202720721222448.5M80.5 kHz250 g
WBU-200N200 N118432432202720721222448.5M80.8 kHz250 g
WBU-500N500 N118432432202720721222448.5M81.4 kHz250 g
WBU-1KN1 kN118432432202720721222448.5M82.6 kHz250 g
WBU-2KN2 kN155532842.52536309017.532.562.513M102.2 kHz480 g

*For confirmation of items not listed, please refer to the operating instructions or contact us.

Specifications

Safe Overload150 %R.C.
Rated Output2 mV/V±0.2 %
Nonlinearity0.015 %R.O.
Hysteresis0.015 %R.O.
Repeatability0.01 %R.O.
Excitation Voltage12 V (or less)
Safe Excitation Voltage20 V
Input Rsistance350 Ω
Output Rsistance350 Ω
Compensated Temp.Range-10~60 ℃
Safe Temp.Range-30~80 ℃
Temp.Effect on Zero0.002 %R.O./℃
Temp.Effect on Output0.0015 %/℃
CableΦ6mm-4wire shielded cable, length : 5m

Instruction Manual&Download drawings

If you wish to download, please register or log in.

Related product

Pick up