SAL

Features
  • Measuring static, dynamic and impulsive accelerations.
  • Small size. High output type.
  • Accuracy class: 1% RO.

Appearance Dimensions

Model and Capacity / Dimension / etc. (unit : mm)

ModelRated valueABCDNatural frequencyFrequency responseWeight
SAL-20MS±20 m/s2(2.039 G)1916162250 HzDC~36 Hz20 g
SAL-50MS±50 m/s2(5.099 G)16161619105 HzDC~80 kHz17 g
SAL-100MS±100 m/s2(10.20 G)16161619155 HzDC~135 Hz17 g
SAL-200MS±200 m/s2(20.39 G)16161619215 HzDC~180 Hz17 g

* The weight indicated in the tables of this data sheet does not include the weight of cables.
* Frequency response range:
The output of this acceleration detector to be always within ±5% when applying constant vibratory accelerations to this acceleration detector and changing the values of applied frequency from time to time.

Specifications

Safe Overload130 %R.C.
Rated Output1.1 mV/V±30 %
Nonlinearity1 %R.O.
Hysteresis1 %R.O.
Transverse sensitivity±3 %R.O.
Damping ratio0.7 (Approx. at 25℃)
Excitation Voltage3 V  (or less)
Safe Excitation Voltage4 V
Input Rsistance120 Ω
Output Rsistance120 Ω
Safe Temp.Range-10~60 ℃
Temp.Effect on Zero0.1 %R.O./℃
Cable 4-core parallel vinyl wire 0.6 m*1

Instruction Manual&Download drawings

If you wish to download, please register or log in.