Registration

Login

PRODUCTS

RCT-ES

Features
  • Wide range of rated capacities (50 N to 2 KN)
  • High precision, compact, for both tension and compression
  • Excellent eccentricity resistance (max. breakaway: 25 mm)
  • Output difference in tension and compression within 0.1 %
  • Suitable for high-precision testing and inspection equipment
  • Accuracy class: 0.05 %

Appearance Dimensions

Model and Capacity / Dimension / etc. (unit : mm)

ModelCapacityABCDEFGHJNatural frequencyWeight
RCT-50NES50 N57602052525M12*1.5,15 deep52M4,7 deep0.4 kHz0.6 kg
RCT-100NES100 N57602052525M12*1.5,15 deep52M4,7 deep0.5 kHz0.6 kg
RCT-200NES200 N57602052525M12*1.5,15 deep52M4,7 deep0.7 kHz0.6 kg
RCT-500NES500 N57602052525M12*1.5,15 deep52M4,7 deep1.1 kHz0.6 kg
RCT-1KNES1 kN57602052525M12*1.5,15 deep52M4,7 deep1.7 kHz0.6 kg
RCT-2KNES2 kN57602052525M12*1.5,15 deep52M4,7 deep1.8 kHz0.6 kg

Specifications

Safe Overload150 %R.C.
Rated Output1.5 mV/V±1 %
Nonlinearity0.05 %R.O.
Hysteresis0.05 %R.O.
Repeatability0.03 %R.O.
Excitation Voltage12 V 以内
Safe Excitation Voltage20 V
Input Rsistance350 Ω
Output Rsistance350 Ω
Compensated Temp.Range-10~60 ℃
Safe Temp.Range-30~80 ℃
Temp.Effect on Zero0.005 %R.O./℃
Temp.Effect on Output0.005 %/℃
CableΦ6mm-4wire shielded cable, length : 5m
Attached connectorPRC03-12A10-7M

Instruction Manual&Download drawings

If you wish to download, please register or log in.

Related product