Registration

Login

PRODUCTS

MRU

Features
  • Φ14 mm and 4 mm in thickness. All stainless steel construction. Ultra-small and high capacities.
  • Load can be sensed on flat surface of Φ4 mm (during uniform loading).
  • Capacities: 200N, 500N and 1kN.
  • Applications: Occlusion force measurement. For installation in industrial machines.

Appearance Dimensions

Model and Capacity / Dimension / etc. (unit : mm)

ModelCapacityNatural frequencyWeight
MRU-200N200 N47 kHz3 g
MRU-500N500 N75 kHz3 g
MRU-1KN1 kN110 kHz3 g

* The weight indicated in the specifications does not include that of the cable.
* Can offer special units with capacities 2kN and 3kN in the external diameter of 17 mm and in the thickness of 5 mm.

Specifications

Safe Overload120 %R.C.
Rated Output1 mV/V±20 %
Nonlinearity2 %R.O.
Hysteresis2 %R.O.
Repeatability1 %R.O.
Excitation Voltage2 V  (or less)
Safe Excitation Voltage3 V
Input Rsistance120 Ω
Output Rsistance120 Ω
Compensated Temp.Range0~60 ℃
Safe Temp.Range-10~60 ℃
Temp.Effect on Zero0.2 %R.O./℃
Temp.Effect on Output0.03 %/℃
CableΦ2mm-4wire shielded cable, length : 2m

*RE: Cable
An extremely thin side wound shielded cable with an excellent bendability is used in this Model of Load Cell. In order for this extremely thin cable to be free from any accidents of being snapped off in the course of operation, it is recommended that this thin cable is connected with the robot cable via relay terminals if the load cell is installed on fluctuating positions.
Although the standard length of the drawn out cable from the load cell is determined to be 2 M, we see no particular effects provided even that the load cells are used with the drawn out cable in the different lengths

Instruction Manual&Download drawings

If you wish to download, please register or log in.