Registration

Login

PRODUCTS

MRD-C

Features
  • Button type. Ultra-small Load Cell.
  • Wide range capacities (10N to 2kN).
  • Low cost.
  • Applications: Pressure controls in press machines. For installation on industrial machines.

Appearance Dimensions

Model and Capacity / Dimension / etc. (unit : mm)

ModelCapacityABCDEFGNatural frequencyWeight
MRD-10NC10 N4123.31.8SR2172.316 kHz2.8 g
MRD-20NC20 N4123.31.8SR2172.322 kHz2.8 g
MRD-50NC50 N4123.31.8SR2172.333 kHz2.8 g
MRD-100NC100 N9.5207.52.5SR425321 kHz5.2 g
MRD-200NC200 N9.5207.52.5SR425328 kHz5.2 g
MRD-500NC500 N9.5207.52.5SR425341 kHz5.2 g
MRD-1KNC1 kN9.5207.52.5SR425359 kHz5.2 g
MRD-2KNC2 kN9.5207.52.5SR425385 kHz5.2 g

* The weight indicated in the specifications does not include that of the cable.

Specifications

Safe Overload150 %R.C.
Rated Output1 mV/V±20 %
Nonlinearity0.3 %R.O.
Hysteresis0.3 %R.O.
Repeatability0.2 %R.O.
Excitation Voltage4 V  (or less)
Safe Excitation Voltage6 V
Input Rsistance350 Ω
Output Rsistance350 Ω
Compensated Temp.Range0~60 ℃
Safe Temp.Range-10~60 ℃
Temp.Effect on Zero0.2 %R.O./℃
Temp.Effect on Output0.1 %/℃
CableΦ2mm-4wire shielded cable, length : 3m(10N to 50N)
 Φ2.8mm-4wire shielded cable, length : 3m(100N to 2kN)

*RE: Cable
An extremely thin side wound shielded cable with an excellent bendability is used in this Model of Load Cell. In order for this extremely thin cable to be free from any accidents of being snapped off in the course of operation, it is recommended that this thin cable is connected with the robot cable via relay terminals if the load cell is installed on fluctuating positions.
Although the standard length of the drawn out cable from the load cell is determined to be 3 M, we see no particular effects provided even that the load cells are used with the drawn out cable in the different lengths

Instruction Manual&Download drawings